    ABSTRAK
    Pemelihara ikan hias di saat pandemi COVID 19 terus meningkat karena
    perawatannya yang sangat sederhana dan tidak membutuhkan ruang yang luas
    untuk merawatnya. Pemeliharaan ikan hias harus rutin dalam membersihkan dan
    merawat akuarium. Diperlukannya sistem pemantauan kekeruhan air pada
    akuarium yang dilengkapi sistem pemantauan kualitas air, mendeteksi kadar
    keasaman dan mendeteksi kekeruhan air pada akuarium. Objek pada penelitian
    adalah kekeruhan air, pH air dan ketinggian air pada akuarium. Adapun penelitian
    dilakukan untuk mengontrol dan juga monitoring kekeruhan, pH air dan
    ketinggian di akuarium dapat dilihat melalui Antares web dan Antares mobile
    sehingga dapat mengetahui kondisi air di dalam akurium setiap saat dan tidak
    akan terjadi keadaan air mengalami kekeruhan, pH air tidak stabil dan yang
    mengalami kelebihan atau kekurangan di dalam akuarium. Hasil pengujian sensor
    Ultrasonik HC-SR04 perbandingan nilai yang dihasilkan selisih rata-rata 0,7.
    Hasil pengujian sensor Turbidity didapati pembacaan sensor apabila pada air
    bersih nilainya kecil dan akan membesar seiring keruhnya air. Dan hasil pengujian
    sensor pH menampilkan adanya perbedaan yang dibaca sensor oleh pH meter dan
    pH sensor dengan selisih rata-rata 0,8 dari pH buffer. Dari hasil uji penelitian ini
    data hasil seluruh sensor dapat dilihat melalui website Antares yang menunjukan
    pada setiap sensor berjalan dengan baik sehingga nilai-nilai yang terinput dari
    sensor kekeruhan (Turbidity), sensor pH, dan sensor ultrasonik HC-SR04
    mendapatkan nilai yang relatif akurat.
    Kata Kunci: ESP32, Sensor Turbidity, Sensor pH, Sensor Ultrasonik, Antares.
    ABSTRACT
    Ornamental fish keepers during the COVID 19 pandemic continue to increase
    because their maintenance is very simple and does not require a large space to
    care for them. Maintenance of ornamental fish must be routine in cleaning and
    caring for the aquarium. There is a need for a water turbidity monitoring system in
    an aquarium that is equipped with a water quality monitoring system, detecting
    acidity levels and detecting water turbidity in aquariums. The objects in this
    research are water turbidity, water pH and water level in the aquarium. The
    research was carried out to control and also monitor turbidity, water pH and
    height in the aquarium which can be seen via the Antares web and Antares mobile
    so that you can find out the condition of the water in the aquarium at any time and
    there will be no turbidity, unstable water pH and those experiencing turbidity.
    advantages or disadvantages in the aquarium. The results of the HC-SR04
    Ultrasonic sensor test result in a comparison of the resulting value with an average
    difference of 0.7. The results of the Turbidity sensor test found that the sensor
    reading when the value is small in clean water and will increase as the water
    becomes turbid. And the results of the pH sensor test show that there is a
    difference that is read by the sensor by the pH meter and the pH sensor with an
    average difference of 0.8 from the pH buffer. From the results of this research test,
    data on the results of all sensors can be seen through the Antares website which
    shows that each sensor is working properly so that the input values from the
    turbidity sensor, pH sensor, and HC-SR04 ultrasonic sensor get relatively accurate
    values.
    Keyword : ESP32, Sensor Turbidity, Sensor pH, Sesor Ultrasonik, Antares.