Final_Project
#15577
TA/JUR.T.ELEKTRO.PS.TEKNIK LISTRIK 014 DID s 2022 ISBN:19612011

Subjects:TEKNIK ELEKTRO Penelitian

    STUDI INSTALASI PENERANGAN GEDUNG MADRASAH IBTIDAIYAH NEGERI (MIN 2) SAMARINDA --

    DIDI JAPUTRA / / /
    Samarinda 2022
    xiv; 123 h; ilus; 29 cm Bahasa:Ind

    ABSTRAK
    Didi Japutra Pembimbing:
    19612011 I. Rusdiansyah, S.T, M.T
    Program Studi Teknik Listrik D-III II. Drs. Abdurrahim, M. Hum
    Studi Instalasi Penerangan Gedung Madrasah Ibtidaiyah Negeri (MIN 2) Samarinda
    Abstrak, Saat ini energi listrik menjadi kebutuhan yang sangat penting di tiap lapisan
    masyarakat. Dalam menjalani kehidupan sehari-hari, hampir seluruh peralatan yang
    digunakan manusia tidak dapat bekerja tanpa adanya energi listrik, terutama pada bagian
    instalasi penerangan. Disamping itu listrik juga dapat menimbulkan bahaya jika lalai dalam
    penggunannya. Penerapan PUIL khususnya pada instalasi bangunan atau gedung sangat
    penting agar mengurangi terjadinya bahaya. Survei langsung ke lapangan, untuk
    melaksanakan studi instalasi penerangan ini perlu dilakukan survei langsung ke lapangan
    agar penulis dapat mengetahui keadaan lokasi gedung MADRASAH IBTIDAIYAH
    NEGERI (MIN 2) SAMARINDA yang dijadikan sebagai tempat melakukan studi instalasi
    penerangan. Wawancara, juga dilakukan dengan pihak yang bersangkutan agar
    memudahkan penulis mendapatkan referensi maupun data-data akurat yang dibutuhkan
    dalam menyelesaikan Laporan Tugas Akhir.Penghitungan jumlah titik lampu dilakukan
    perbandingan contoh ruang kelas IV.A hasilnya berbeda. Pengaman data lapangan dengan
    hasil penghitungan didapatkan perbandingan berbeda, data lapangan yakni menggunakan
    pengaman utama MCB 1 Phase 40 A hasil penghitungan pengaman utama MCB 3 Phase
    50 A. Pada penghantar data lapangan dengan data hasil penghitungan didapatkan
    perbandingan berbeda data lapangan penghantar sirkit akhir NYM 1 x 2,5 mm2hasil
    penghitungan penghantar sirkit akhir NYM 2 x 2,5 mm2. Pada sirkit cabang group Phase
    R, S, dan T adalah penghantar NYM 2 x 4 mm2, pada kondisi lapangan tidak terdapat
    pembagian sirkit cabang. Pada sirkit utama kabel NYY 4 x 6 mm2, pada kondisi lapangan
    penghantar yang digunakan pada sirkit utama adalah NYM 4 x 2,5 mm2. Intensitas
    penerangan yang akan digunakan harus disesuaikan lagi dengan fungsi ruangan.
    Kata Kunci: Instalasi Penerangan, Lampu, Pengaman, Penghantar.
    vii
    ABSTRACT
    Didi Japutra Mentor:
    19612011 I. Rusdiansyah, S.T, M.T
    Program Studi Teknik Listrik D-III II. Drs. Abdurrahim, M. Hum
    Study on Lighting Installation of the State Islamic Madrasah Building 2 Samarinda
    Abstract, Currently, electrical energy is a very important need in every level of society.
    In living daily life, almost all equipment used by humans cannot work without electrical
    energy, especially in the lighting installation section. Besides, electricity can also pose a
    danger if it is negligent in its use. The application of PUIL, especially in the installation of
    buildings or buildings, is very important in order to reduce the occurrence of hazards.
    Direct survey to the field, to carry out this study of lighting installations, it is necessary to
    conduct a direct survey to the field so that the authors can find out the condition of the
    location of the MADRASAH IBTIDAIYAH NEGERI (MIN 2) SAMARINDA building which
    is used as a place to conduct a study of lighting installations. Interviews were also
    conducted with the parties concerned to make it easier for the authors to get references
    and accurate data needed in completing the Final Project Report. The calculation of the
    number of light points was carried out by comparing the examples of class IV.A the results
    were different. Field data security with the calculation results obtained a different
    comparison, field data using the main safety MCB 1 Phase 40 A the results of the
    calculation of the main safety MCB 3 Phase 50 A. In the field data conductor with the
    calculated data obtained a different comparison of field data for the final circuit conductor
    NYM 1 x 2.5 mm2 calculation result of final circuit conductor NYM 2 x 2.5 mm2. In the
    branch circuits of the Phase R, S, and T groups, the NYM conductors are 2 x 4 mm2, in
    field conditions there is no distribution of branch circuits. In the main circuit NYY cable 4
    x 6 mm2, in the field conditions the conductor used in the main circuit is NYM 4 x 2.5 mm2.
    The intensity of the lighting to be used must be adjusted again to the function of the room.
    Keywords: Installation of lighting, Lamps, Safety, Conductors.